250 research outputs found

    Commissioning of the DAΦNE beam test facility

    Get PDF
    Abstract The DAΦNE Beam Test Facility (BTF) is a beam transfer line optimized for the production of electron or positron bunches, in a wide range of multiplicities and down to single-electron mode, in the energy range between 50 and 800 MeV . The typical pulse duration is 10 ns and the maximum repetition rate is 50 Hz . The facility design has been optimized for detector calibration purposes. The BTF has been successfully commissioned in February 2002 and started operation in the same year in November. The schemes of operation, the commissioning results, as well as the first users' experience are reported here

    Measurements and calibration of the stripline BPM for the ELI-NP facility with the stretched wire method

    Get PDF
    A methodology has been developed to perform electrical characterization of the stripline BPMs for the future Gamma Beam System of ELI Nuclear Physics facility in Romania. Several prototype units are extensively benchmarked and the results are presented in this paper. The BPM sensitivity function is determined using a uniquely designed motorized test bench with a stretched wire to measure the BPM response map. Here, the BPM feedthroughs are connected to Libera Brilliance electronics and the wire is fed by continuous wave signal, while the two software-controlled motors provide horizontal and vertical motion of the BPM around the wire. The electrical offset is obtained using S-parameter measurements with a Network Analyzer (via the “Lambertson” method) and is referenced to the mechanical offse
    • …
    corecore